NEMA 5-20P Convert to NEMA 5-15P
I have a device I am wanting to use which will work with a 15 or 20 amp circuit. However all I have are NEMA 5-15P plugs and the device has NEMA 5-20P plugs. Are there converters out there to change these plugs? Something similar to going from a three prong to a two prong? Thanks for your help all! I believe what you mean is that you have all 5-15R receptacles. (The R is for receptacle, the P is for plug.) Any device that has a 5-20P plug is to be used only on a 20 amp circuit. Any device with that plug style should not be used on a 15 amp circuit. That's why they are required to provide the 5-20P plug. Also, no receptacle connected to a 15 amp breaker or fuse should be a 5-20R. I would determine which 20 amp circuit or circuits in my home I would use this device on and change the receptacle nearest where it would be used to a 5-20R. You probably know this but I'll mention it - a 5-20R receptacle will accomodate either standard 5-15P and 5-20P plugs. Juice. Juice, You are correct I have 5-15R's in my home but for some reason the breakers which connect to these circuits are rated at 20amp. So I was wondering if given my setup if I could use a a converter of sort to convert the 5-20P to work with a 5-15R or could I just replace the 5-15R with a 5-20R. If I have the correct 20amp circuit and not the correct recpticle can I still replace it even if there may other other 5-15R's hangling off the circuit? There are no converters to allow a 20a cord end to be plugged into a 15a receptacle. The 5-20p is on the deivce you have because of its higher amp draw. Juice is right, if you can change a receptacle on one of the 20a circuits to a 5-20R receptacle.You'll want to choose a circuit that has the fewest loads on it to avoid tripping the breaker.You must be certain it is a 20a circuit as installing a 20a receptacle on a 15a circuit is a code violation.
Related Posts:
Question about surge protection and gfci use
question about surge protection and GFCI usehere is the situation. we have an old house, it has the 2 prong outlets so no ground. I want to be able to plug a surge protector in to protect TV and o...
Pool pump quitcapacitor bad
pool pump quit-capacitor bad?I have a pool pump with a 2HP motor. End of last season it quit working but since I was going to be closing pool I never dealt with it. I started to look at it, and fo...
Mtd yardman rototiller starts but wont run
MTD Yardman rototiller starts but won't runWe just got a used 5.5 hp MTD Yardman rototiller. model # 21A-394-401 Serial # 1C150k50447 with a Brigg's and Stratton engine #110402 0161 E1 It had bee...
Pest control
Pest controlI have in-wall pest control tubes installed in my home. Can I service these myself? If so, what procedure should I use, and what pesticide should I use? I do have an air compressor. DI...
Recipies for refractory cement
recipies for refractory cement?anybody know a recipie for refractory cement? There is no recipe for refractory cement that can be mixed by hand. You can use fire clay with a small amount of portla...